AllianceSensors.com - H.G. Schaevitz LLC Click here for Home Page       

            

Products By Application

  • Aerospace / Military
  • Civil Engineering
  • Energy and Power Generation
  • Factory Automation Linear Position Sensors
  • Hydraulic Cylinder Position Sensors
  • Industrial / OEM
  • Subsea / Marine Hydraulics
  • Mobile Hydraulics
  • Motor Sports

Products By Type

  • Hydraulic Cylinder Position Sensors
    • Embedded
    • Port Mounted
  • Linear Position Sensors
    • LVIT Position Sensors
      • LVIT - Industrial Automation
      • LVIT - Heavy Duty Industrial
      • LVIT - Extreme Duty
    • LVDT Position Sensor Products
      • LVDT - Power Generation
      • LVDT - Heavy Duty
      • LVDT - Industrial
    • LVDT - Gauging Probes
      • Digital Gauging Probes
      • Analog Gauging Probes
    • Linear Potentiometer Position Sensor
  • Sensor Signal Conditioning and Instrumentation
  • Temperature Sensing Products
    • Temperature Probes
    • Thermocouple Heads
    • Pyrometer Meters and Electronics
    • Pyrometer Kits
  • Rotary Sensors
    • All Rotary Sensors
  • Sensor Mounting Accessories
  • Spring Loaded LVIT

Technical Information

  • Product Catalog
  • Application Notes
    • Linear Position Sensor
    • LVDT Position Sensor
    • LVDT Signal Conditioning
    • Rotary Position Sensor
    • Position Sensor Technology Comparison
  • Datasheets
  • Manuals
    • Product Manuals
  • FAQ
    • Linear Position Sensor FAQ
    • LVDT Position Sensor FAQ
    • LVDT Signal Conditioning FAQ
    • Rotary Position Sensor FAQ
    • Position Sensor Technology Comparison
  • Downloads
    • GUI Software for SC-100
    • GUI Software for S1A

Corporate Info

  • Contact Us
  • Reps and Distributors
  • About Our Company
    • About Our Company
    • Alliance Sensors Group Terms and Conditions
    • RMA Evaluation Fees for returns
  • News Articles
    • The Three Rs of Sensors
    • True Cost of Ownership - parts 1, 2, and 3
    • LVIT Technology Factory Automation
    • LVIT Technology: What is it and where does it fit into the sensor world?
    • Industrial Trends
    • Position Sensor Technology Comparison for hydraulic cylinder feedback
    • Bridge Monitoring Systems
    • GE Position Sensors on Power Gen Turbines
    • What's So Good About LVIT Technology
    • LVIT Technology™ Solves the Age Old Problem- Reliability vs Cost
    • S1A Used to Solve Multi-channel LVDT Measurement System Susceptibly
  • Press Releases
  • Site Map

S1A Used to Solve Multi-channel LVDT Measurement System Susceptibly

H. G. Schaevitz LLC, Alliance Sensors Group has solved the age old problem of cross talk between sensors even if the master signal conditioner fails.

When LVDT signal cables are bundled together or laid close to each other in a wire trough, even for short distances, the result can be a mutual interference phenomenon called heterodyning or “beating”. This effect is created when the frequencies of the oscillator in the individual signal conditioner driving the excitation signal to each LVDT vary slightly. Since the signal cables are close together, they can capacitively couple among each other, resulting in a very low frequency signal that is the difference between the frequencies of the individual oscillators. This difference frequency signal can ride on the DC output of the LVDT signal conditioners, appearing as low frequency ripple or noise with a period measured in fractions of a second, or as a repetitive slow drift with a period of many seconds. When a pair of LVDTs are used together for redundancy, this effect may be evident on only one channel of the system. In systems with larger numbers of LVDT channels, this effect may be found in one or more channels, depending on many factors like cable length and layout as well as shielding and grounding.

The chart below show an example of this drifting over time on the left side and the elimination of the effect utilizing the Master/Slave function.

Graph is courtesy of Rawhide Energy Station, Platte River Power Authority, Fort Collins CO.

The waveform above in the output was noted in right reheat and intercept valve positioners that was using dual LVDTs in redundant systems. The master / slave function removed the beat frequency signal and the waveform flattened.

Typically the way to solve this problem in multiple channel systems is to create a “master” oscillator by using the oscillator from one of the signal conditioners to supply the same excitation frequency to all of the LVDTs. The oscillators in the other LVDT signal conditioners are overridden by the master and considered “slaves”. The idea is that there cannot be any beat frequency interference if all the LVDTs are operating at the exact same frequency.

This practice works quite well but has a major drawback, because the "redundant" system is no longer fully redundant. The system is now dependent on one oscillator in one signal conditioner to supply all the LVDTs with the proper excitation frequency. If the master fails, two things could happen: either your other channels stop operating, or they revert back to their original oscillator frequencies and the multiple channel DC outputs now display beat- frequency-produced noise, ripple, or output drifting. Many companies offer LVDT signal conditioners with a master/slave function, but they all are fully susceptible to the beat frequency problem if the designated master oscillator falters or fails. Sometimes when LVDTs are used in a redundant pair this will be evident on only one channel of the system. In multiple channels it can cause similar effects in one or multiple channels or none and depends on many factors like cable layout, grounding, shielding along with various cable lengths etc.

Alliance Sensors Group has considered this beat frequency problem with multiple LVDT installations and developed a successful solution to this problem. Because the S1A and its variants have a digital address for RS485 communication capability, we are able to use this digital feature to maintain the full redundancy of multiple LVDT systems. If the "master" were to fail, another "master" having a different digital address would instantly come on stream to maintain a single excitation frequency. In this approach the only thing lost in a "master" oscillator failure is the former master channel itself. For multiple channel LVDT systems, the integrity of the output signals from the other channels is fully maintained. This "auto-mastering" feature is unique to the Alliance Sensors S1A and its variants.

For more information on Alliance Sensor Group call us at 856-727-0250 or contact us by clicking here.

View Most Commonly Used Signal Conditioners Here! 

 

Our Technical Support Staff:  We have more than 150 years and three generations in the position sensor business and are expert application engineers at what we sell. We have real world experience and know how to solve your measurement challenges. Need technical help with your measurement application? Call us today 856-727-0250. 

Our Web Site: We are constantly improving our website and adding new sensors to our product offerings.

 

Authorized 

Distributors For:

HGSI Temperature Sensing Products

Temperature Sensing Products

Have a Question?

Need pricing or have questions about a product?

Speak to an experienced application engineer at H. G. Schaevitz Alliance Sensors Group by calling us at 856-727-0250 or contact us by clicking here.

We will provide you with fast reliable service the first time you call.

Popular Content

Today's:

  • Contact Us
  • About Our Company HG Schaevitz LLC Alliance Sensors Group
  • LVDT Signal Conditioner DIN Rail Mounted SC-200 Series

All time:

  • About Our Company HG Schaevitz LLC Alliance Sensors Group
  • LVDT Signal Conditioner DIN Rail Mounted S1A Series SUPERCEDED BY S2A

Last viewed:

  • Contact Us
  • The Three Rs of Analog Position Sensor-based Mechanical Measurements
  • Press Releases